Ice buildup on outdoor units exposed to open-field wind
Why it happens here
Greely's rural-edge properties sit on lots with little windbreak, and sustained wind accelerates frost formation on the outdoor coil. Units in these locations cycle into defrost more often, and if the drain path freezes, meltwater backs up and refreezes around the base. This is worse on pads that were not set with frost movement in mind.
Our approach
We site outdoor units with wind exposure in mind, use a properly sized pad, and route the condensate drain so it cannot pool and freeze. We also check defrost parameters during commissioning and adjust them for our humidity profile rather than leaving factory defaults in place.